Rakour · 72V DC 4-Inch Solar Submersible Pump with Plastic Impellers

72V DC 4-Inch Solar Submersible Pump with High-Flow Impellers (750W, 56m)

Model 4DPC6-56-72-750

High-capacity 4-inch borehole solar pump with 750W (1.0 HP) power, 6.0 m3/h maximum flow, and 56m maximum head. High-efficiency 72V BLDC motor and sand-tolerant multi-stage impellers for agricultural irrigation.

Minimum Well Diameter
4.0 in (100 mm)
Engineered for standard 100mm, 125mm, and 150mm borehole casings
Rated DC Voltage
72V DC
Optimum MPPT input window between 90V and 120V DC
Rated Motor Power
750W (1.0 HP)
High-torque permanent magnet brushless DC (BLDC) motor
Maximum Flow Rate
6.0 m3/h (100 L/min)
High-volume delivery for commercial orchard and crop irrigation
Maximum Vertical Head
56m (184 ft)
Zero-flow shut-off ceiling; continuous duty between 20m and 48m
Discharge Connection
1 1/4 in (32 mm)
Corrosion-resistant AISI 304 stainless steel threaded female outlet
Factory Wholesale FOB $165.00 – $210.00 USD / unit

Tiered by order volume & controller kit · Request official quotation

Product overview

High-capacity 4-inch borehole solar pump with 750W (1.0 HP) power, 6.0 m3/h maximum flow, and 56m maximum head. High-efficiency 72V BLDC motor and sand-tolerant multi-stage impellers for agricultural irrigation.

Model 4DPC6-56-72-750

72V DC 4-Inch Solar Submersible Pump with Plastic Impellers

Minimum Well Diameter
4.0 in (100 mm)
Rated DC Voltage
72V DC
Rated Motor Power
750W (1.0 HP)
Maximum Flow Rate
6.0 m3/h (100 L/min)

Hydraulic & Mechanical Performance

The 4DPC6-56-72-750 provides an expansive operational envelope for agricultural irrigation and municipal storage replenishment. The duty matrix below details verified discharge rates across realistic Total Dynamic Head (TDH) elevations based on factory curve P07.

6.0 m3/h (100 L/min) Maximum Flow
56m (184 ft) Maximum Head
  • Calculate Total Dynamic Head (TDH) by summing static water level, seasonal drawdown, vertical elevation rise, and friction losses through 1 1/4-inch riser pipe.
  • The multi-stage polymer impellers handle suspended sand concentrations up to 40 g/m³ without performance loss.
  • Maintain a minimum submergence depth of 2.0 meters below the dynamic pumping water level at all times.

Electrical & Solar Parameters

Three 370W to 400W monocrystalline solar modules connected in series, supplying 105V to 118V Vmp under peak irradiance.

  1. Rated Voltage 72V DC
  2. Optimum MPPT Range 90V to 120V DC
  3. Motor Architecture Brushless DC Canned Wet-Rotor Motor (BLDC)

Product features

High-Volume Multi-Stage Polymer Wet End

Engineered multi-stage POM impellers generate high volumetric delivery up to 6.0 m³/h with lower rotational inertia, ensuring prompt morning startup under marginal solar irradiance.

1.0 HP Brushless DC Synchronous Motor

Permanent magnet 72V BLDC wet-rotor motor delivers over 88% electromechanical conversion efficiency, running cool under continuous daytime pumping.

Floating Impeller Sand-Clearing Geometry

Hydraulic stages incorporate axial clearance channels that purge suspended silt and fine sand particles, preventing mechanical seizure in unlined boreholes.

Intelligent External MPPT Electronic Controller

Tracks peak photovoltaic power curves between 90V and 120V DC while managing automatic well dry-run protection and storage cistern overflow sensors.

Hydraulic performance

Hydraulic Performance Matrix & Operating Points

The 4DPC6-56-72-750 provides an expansive operational envelope for agricultural irrigation and municipal storage replenishment. The duty matrix below details verified discharge rates across realistic Total Dynamic Head (TDH) elevations based on factory curve P07.

  1. Calculate Total Dynamic Head (TDH) by summing static water level, seasonal drawdown, vertical elevation rise, and friction losses through 1 1/4-inch riser pipe.
  2. The multi-stage polymer impellers handle suspended sand concentrations up to 40 g/m³ without performance loss.
  3. Maintain a minimum submergence depth of 2.0 meters below the dynamic pumping water level at all times.
Hydraulic performance curve for the Rakour 4DPC6 solar submersible deep well pump series

Operating Head vs Flow Duty Matrix

4DPC6-56-72-750
Operating Head (TDH) Discharge Flow Rate Recommended Duty Scenario
15 m (49 ft) 5.6 m3/h (93.3 L/min) Shallow borehole pumping, open canal delivery, and bulk surface reservoir filling Maximum volumetric throughput delivering up to 36 m³ per clear solar irrigation day
30 m (98 ft) 4.5 m3/h (75.0 L/min) Primary operating duty point for multi-zone orchard drip lines and micro-sprinklers Optimal dynamic pressure (3.0 bar) balanced with strong volumetric flow rate
45 m (148 ft) 2.8 m3/h (46.7 L/min) Medium-depth borehole extraction lifting water to elevated hilltop holding tanks Stable pressurized discharge against substantial vertical topographic static head
56 m (184 ft) 0.0 m3/h (0.0 L/min) Zero-flow shut-off head ceiling; upper hydraulic threshold of the pump stack Design operating working points safely below 50m head to prevent zero-flow thermal rise

Technical specifications

Electrical & Solar Parameters

Rated Voltage
72V DC
Optimum MPPT Range
90V to 120V DC
Rated Motor Power
750W (1.0 HP)
Maximum Array Voc
Less than 170V DCArray Voc must remain below 170V under minimum local ambient temperature
Motor Architecture
Brushless DC Canned Wet-Rotor Motor (BLDC)

Hydraulic & Mechanical Performance

Maximum Flow
6.0 m3/h (100 L/min)
Maximum Head
56m (184 ft)
Discharge Outlet
1 1/4 in (32 mm) NPT/G female
Hydraulic Stack
Multi-stage centrifugal high-flow impeller assembly
Submersible Lead
2.0m heavy-duty factory submersible drop cable

Construction & Material Standards

Outer Pump Shell
Seamless AISI 304 stainless steel barrel
Impellers & Diffusers
Wear-resistant virgin POM/PPO engineering polymer
Motor Shaft
AISI 316 / 304 high-tensile stainless steel
Bearings & Seals
Silicon carbide mechanical seal with carbon thrust bearings

Photovoltaic Sizing & Matching

Solar Array Sizing Guide

Recommended PV Array Power
1000W - 1200W PV Array
Recommended Panel Configuration
3 × 370W-400W Monocrystalline Panels in Series (Vmp ~105V-118V, Voc < 145V)
Array Voc Safety Ceiling
Optimum MPPT: 90V - 120V DC | Absolute Maximum Voc: < 170V DC
  • Direct Photovoltaic Drive: Operates directly from solar panels without costly battery banks; digital MPPT firmware maximizes daily pumped volume.
  • Solar Oversizing Factor: Sizing solar array capacity at 1.3× to 1.4× rated motor power (750W) guarantees reliable full-speed operation even during hazy afternoon hours.
  • Cold-Weather Voc Verification: Calculate panel open-circuit voltage at your installation coldest recorded ambient morning to ensure total array Voc never exceeds 170V DC.

Global B2B Logistics

Packaging & Logistics

Packaging Format
Reinforced Heavy-Duty Export Carton with Custom High-Density Molded Foam
Crate Dimensions (L×W×H)
890 × 240 × 140 mm
Volume (CBM)
0.0299 m³ (Approx. 33 units per 1.0 CBM)
Gross / Net Weight
11.50 kg / 9.40 kg
Customs HS Code
8413709190

Standard Package Contents

  • Rakour 4DPC6-56-72-750 Submersible Pump Unit with 2.0m Factory Lead
  • Intelligent IP65 External DC MPPT Pump Controller
  • Wellhead Dynamic Water-Level Sensor Probes with Submersible Wire
  • Elevated Storage Tank Overflow Float Switch Assembly
  • Dual-Wall Waterproof Heat-Shrink Splice Tubing Kit with Hot-Melt Adhesive
  • High-Dielectric Self-Amalgamating Waterproof Electrical Tape
  • Spare Multi-Stage Wear-Resistant Impeller & Diffuser Kit
  • Comprehensive Multilingual Installation and Electrical Commissioning Manual

Rakour Engineering Field Sizing

Engineering In-Depth Analysis

Hydraulic Engineering: 4-Inch Multi-Stage High-Flow Extraction

Standard 4.0-inch (100 mm) boreholes account for over 70% of agricultural wells globally. Extracting groundwater efficiently from these casings requires balancing motor diameter, annular cooling clearance, and stage volume. The Rakour 4DPC6-56-72-750 satisfies this engineering benchmark by coupling a 750W (1.0 HP) permanent magnet brushless DC motor with a multi-stage centrifugal polymer wet end. Delivering up to 6.0 m³/h (100 L/min) capacity and reaching a 56m shut-off head, this 72V system supplies high throughput for mid-depth aquifers without diesel fuel costs.

Each hydraulic stage incorporates a precision-molded POM impeller encased within a reinforced PPO diffuser. Virgin polymers present smooth surfaces that minimize friction drag compared to cast metals, yielding high efficiency at low rotational inertia. The floating impeller geometry incorporates axial sand-relief passages. When pumping unlined boreholes with suspended silt, abrasive particles pass through clearance gaps rather than wedging against static walls. For operations requiring extreme abrasive resistance against coarse quartz sand, our 4DSC3.5-50-48-400 stainless steel pump provides an all-metal alternative.

Agronomic Sizing: Powering Commercial Drip & Micro-Sprinkler Blocks

Commercial fruit orchards, vineyards, and field crop operations depend on reliable irrigation volumes delivered at stable working pressures. Operating within its nominal duty range of 25 to 40 meters Total Dynamic Head (TDH), the 4DPC6-56-72-750 supplies steady discharge rates between 3.6 and 5.0 m³/h. On a typical sunny day with 6 to 8 peak sun hours, this system delivers 25,000 to 36,000 liters directly into field distribution networks.

The 1 1/4-inch (32 mm) threaded stainless steel discharge head matches standard agricultural poly riser pipes, reducing turbulent friction. At 30 meters of dynamic head, the unit sustains 3.0 bar of pressure at the wellhead manifold. This pressure directly feeds disc filter banks and pressure-compensating drip lines across 2.5 to 4.0 hectares without booster pumps. To integrate this model into broader farm irrigation designs, explore our technical guide on solar irrigation systems for commercial farms, which details zoned solenoid sequencing and automated reservoir replenishment.

72V Brushless DC Motor & Digital MPPT Controller Architecture

The drive core of the 4DPC6-56-72-750 is a 72V DC permanent magnet synchronous brushless motor (BLDC). Rare-earth neodymium rotor magnets generate strong flux density without rotor winding losses, achieving conversion efficiencies exceeding 88%. The wet-rotor canned design uses filtered borehole water for internal lubrication and stator cooling, eliminating oil chambers that risk contaminating groundwater.

The external IP65 controller executes high-speed MPPT firmware across an optimum DC input voltage window of 90V to 120V. Sizing the photovoltaic generator at 1000W to 1200W peak capacity—such as three 370W-400W monocrystalline modules wired in series—provides sufficient voltage overhead for smooth soft-start pump rotation at low morning sun angles.

Critical Electrical Sizing Note: Photovoltaic panel open-circuit voltage rises sharply under cold ambient temperatures. Sizing calculations must verify that total array Voc under minimum local winter temperatures never exceeds the controller 170V DC absolute limit to avoid overvoltage trip.

The electronic controller displays rotational speed (RPM), motor current, DC bus voltage, and power consumption. Automated safety logic includes down-hole dry-run cutoffs via water level probes and automatic tank shut-off switches. For remote pasture watering setups, review our dedicated remote livestock solar water stations for tank storage calculations.

Systematic Portfolio Comparison: Sizing Against Alternative Aquifer Profiles

Selecting the correct borehole pump model depends on matching dynamic aquifer yield, casing diameter, and static lifting height:

Pump ModelWell CasingRated PowerMax Flow ($Q_{max}$)Max Head ($H_{max}$)Impeller ArchitecturePrimary Application
4DPC6-56-72-7504.0 in (100 mm)750W (72V)6.0 m³/h56 mPOM Multi-StageHigh-flow orchard irrigation & bulk water transfer
4DSC3.5-50-48-4004.0 in (100 mm)400W (48V)3.5 m³/h50 mAISI 304 Stainless SteelMedium-flow boreholes with heavy abrasive sand
3DPC3.5-35-24-3003.0 in (75 mm)300W (24V)3.5 m³/h35 mPOM Multi-StageCompact hand-drilled narrow boreholes
3DSS1.7-100-48-5003.0 in (75 mm)500W (48V)1.7 m³/h100 mProgressive Cavity ScrewDeep groundwater aquifers requiring extreme vertical lift
DCPM21-14-72-750Surface750W (72V)21.0 m³/h14 mCast Iron CentrifugalHigh-volume open canal transfer & secondary booster

If your water source involves river diversion or secondary pressurization from surface storage dams, consider combining this borehole pump with our solar surface pumps for multi-stage distribution. Review our complete catalog of solar submersible pumps or consult our detailed engineering pump selection guide for hydraulic friction tables.

Borehole Installation Protocols & Mechanical Integrity

Maintaining reliable long-term service life requires disciplined mechanical installation procedures:

  1. Setting Depth & Annular Clearance: Hang the pump at least 2.0 to 3.0 meters above the borehole bottom. Placing the unit directly in bottom sediment blocks motor cooling flow, causing thermal degradation of stator windings.
  2. Mechanical Suspension: Never support the pump weight by the power cable or poly delivery pipe. Attach a dedicated 3.0 mm AISI 304 stainless steel safety suspension wire to the cast hoisting lugs.
  3. Hydraulic Non-Return Valve: In vertical riser lines exceeding 30 meters, install an external spring-loaded check valve 1.5 meters above the pump discharge port to absorb kinetic fluid backflow and mitigate water hammer.
  4. Waterproof Cable Splice: Submersible lead splices must be sealed using dual-wall polyolefin heat-shrink tubing lined with hot-melt adhesive, followed by self-amalgamating waterproof rubber tape.
  5. Cavitation Prevention: Fasten down-hole low-water probes at least 1.0 meter above the pump intake screen. If the dynamic water table drops near the intake, the controller automatically triggers a 30-minute cooling rest before re-testing water availability.

Rakour fluid engineers provide complete technical support, CAD dimensional drawings, and photovoltaic string calculations for custom commercial projects. Contact our technical team to verify operating points for your specific borehole data.

Recommended applications

Commercial Farm Drip Irrigation

Supplies steady 3.0 bar pressure directly into drip lines across 2.5 to 4.0 hectares of fruit orchards, vineyards, or field vegetables.

Community & Livestock Water Supply

Fills large communal livestock troughs and pastoral distribution tanks at rates up to 36 m³ daily without fuel costs.

Agricultural Holding Tank Filling

Extracts groundwater from 30 to 45 meter boreholes to fill ground cisterns, enabling gravity-fed overnight distribution.

Rural Micro-Sprinkler Systems

Delivers strong 4.5 m³/h volumetric output at 30m dynamic head to power overhead greenhouse and field micro-sprinklers.

System configuration

  1. Photovoltaic Power Generator

    Three 370W to 400W monocrystalline solar modules connected in series, supplying 105V to 118V Vmp under peak irradiance.

  2. Smart MPPT System Controller

    IP65 weather-sealed electronic unit executing real-time maximum power point tracking and automated dry-run shutdown.

  3. Heavy-Duty Submersible Drop Cable

    Three-core insulated copper drop cable sized to maintain voltage drop below 3% along deep borehole installations.

  4. Riser Pipe & Check Valve Assembly

    1 1/4-inch HDPE or threaded stainless steel riser pipe equipped with a spring-loaded non-return check valve installed 1.5m above the outlet.

Installation notes

  1. Suspend the pump unit at least 2.0 to 3.0 meters above the borehole bottom to prevent silt and gravel ingestion into the lower stage.
  2. Secure the power cable to the 1 1/4-inch riser pipe using UV-stabilized cable ties spaced at 2.0-meter intervals.
  3. Support pump mechanical weight using a dedicated AISI 304 stainless steel safety cable fastened to the cast hoisting lugs.
  4. Position down-hole water level probes at least 1.0 meter above the pump suction inlet to prevent dry-run cavitation damage.
  5. Seal all submersible electrical splices using dual-wall polyolefin heat-shrink sleeves lined with hot-melt waterproof adhesive.

Product FAQ

Review verified technical data, operating limits and the project information needed to evaluate this model.

How does the 4DPC polymer impeller perform in sandy agricultural boreholes?

The 4DPC6-56-72-750 utilizes multi-stage virgin POM/PPO engineering polymer impellers featuring hydrodynamic sand-clearing vanes. These impellers flex microscopically under fine grit impact, preventing particle jamming and resisting silt scouring up to 40 g/m³. For boreholes with severe quartz grit exceeding 50 g/m³, our stainless steel 4DSC series provides an even more rigid alternative.

What solar panel array configuration is recommended for the 72V 750W motor?

We recommend a solar array between 1000W and 1200W composed of three 370W to 400W monocrystalline modules wired in series. This string delivers an operating Vmp of 105V to 118V inside the controller optimal 90V-120V MPPT window, while ensuring total open-circuit voltage stays comfortably below the 170V Voc ceiling even on cold sub-zero mornings.

Can the 4DPC6-56-72-750 fit inside a standard 4-inch well casing?

Yes. The pump outer barrel measures 96mm, engineered precisely for standard 4-inch (100mm inside diameter) borehole casings. The resulting annular gap ensures cooling water flows upward past the stainless steel motor shell at velocities exceeding 0.15 m/s, safeguarding stator insulation against overheating during long pumping cycles.

Does the pump deliver 6.0 m³/h at its maximum 56m head?

No. In centrifugal hydraulic systems, flow varies inversely with head. 6.0 m³/h represents maximum discharge at near-zero head, while 56m is the zero-flow shut-off ceiling. At a typical working depth of 30 meters Total Dynamic Head (TDH), the pump produces 4.5 m³/h (75 L/min), yielding an optimal balance of dynamic pressure and water volume.

What are the export packaging specifications and logistics weights?

Each complete set is packaged in an export-grade reinforced corrugated carton with molded high-density foam cushioning measuring 890 × 240 × 140 mm. Gross shipping weight is 11.50 kg (net weight 9.40 kg) with an individual carton volume of 0.0299 CBM. The international HS customs tariff code is 8413709190.

Project sizing support

Match this pump to your site

Share the water source, required flow, total head and pipe route. Rakour will help check the operating point.

Request a quote