Rakour

2-Inch 24V DC Solar Submersible Pump

Model 2DPC1.5-35-24-200

A 200W Rakour 2DPC solar submersible pump with a plastic impeller, rated for up to 1.5 m3/h maximum flow and 35m maximum head.

Rated voltage
24V DC
Rated power
200W
Maximum flow
1.5 m3/h
Catalogue maximum; actual flow depends on total head.
Maximum head
35m
Catalogue maximum; not the flow point at 1.5 m3/h.
Outlet
3/4 in
Cable length
2m

Product overview

A 200W Rakour 2DPC solar submersible pump with a plastic impeller, rated for up to 1.5 m3/h maximum flow and 35m maximum head.

Model 2DPC1.5-35-24-200

2-inch DC solar submersible pump with plastic impeller

Rated voltage
24V DC
Rated power
200W
Maximum flow
1.5 m3/h
Maximum head
35m

Hydraulic data

The catalogue lists 1.5 m3/h maximum flow and 35m maximum head. These are boundary values, not one simultaneous operating point. Confirm the required flow at the calculated total dynamic head before selecting the pump.

1.5 m3/h Maximum flow
35m Maximum head
  • Calculate total dynamic head from water level, elevation, pipe friction and required outlet pressure.
  • Do not assume the pump delivers 1.5 m3/h at 35m head.
  • Confirm the final operating point against verified performance data before ordering.

Electrical data

Configure the array for a 30V to 48V operating input while keeping total open-circuit voltage below 60V.

  1. Rated voltage 24V DC
  2. Optimum DC input voltage 30V to 48V
  3. PV open-circuit voltage Less than 60V

Product features

2-inch submersible format

The model belongs to the compact 2DPC series of 2-inch DC solar submersible pumps.

Plastic impeller construction

The catalogue identifies the 2DPC range as a plastic-impeller solar submersible pump series.

24V DC electrical platform

The pump is rated at 24V DC with an optimum DC input range of 30V to 48V.

Defined hydraulic limits

Catalogue limits of 1.5 m3/h maximum flow and 35m maximum head support initial model screening.

Hydraulic performance

Use the maximum values as selection boundaries

The catalogue lists 1.5 m3/h maximum flow and 35m maximum head. These are boundary values, not one simultaneous operating point. Confirm the required flow at the calculated total dynamic head before selecting the pump.

  1. Calculate total dynamic head from water level, elevation, pipe friction and required outlet pressure.
  2. Do not assume the pump delivers 1.5 m3/h at 35m head.
  3. Confirm the final operating point against verified performance data before ordering.
Hydraulic performance curves for the Rakour 2DPC series, including 2DPC1.5-35-24-200

Technical specifications

Hydraulic data

Maximum flow
1.5 m3/h
Maximum head
35m
Outlet
3/4 in

Maximum flowMaximum catalogue value; flow falls as total head rises.

Maximum headMaximum catalogue value; it is not produced together with maximum flow.

Electrical data

Rated voltage
24V DC
Optimum DC input voltage
30V to 48V
Rated power
200W
PV open-circuit voltage
Less than 60VThe complete array Voc must remain below this catalogue limit.

Construction and connection

Series
2DPC
Pump format
2-inch submersible pump
Impeller
Plastic
Cable length
2m

Recommended applications

Small-volume water lifting

A potential use where the required flow and total dynamic head remain inside the verified operating range.

Solar tank filling

The 24V DC model can be evaluated for daytime tank filling after daily volume and effective solar hours are calculated.

Small irrigation water supply

It may supply a matched irrigation zone or storage tank when the required pressure and flow are confirmed.

Remote water transfer

It can be considered for off-grid transfer duties that match its electrical and hydraulic limits.

System configuration

  1. Solar array

    Configure the array for a 30V to 48V operating input while keeping total open-circuit voltage below 60V.

  2. Compatible controller

    Select a controller suitable for a 24V DC pump and the electrical limits of the complete system.

  3. 2DPC submersible pump

    Install the pump with suitable clearance, support and submergence for the water source.

  4. Delivery line

    Size the 3/4-inch connection, pipe route and outlet so avoidable friction does not consume available head.

Installation notes

  1. Confirm that the bore, casing or water source can accept the 2-inch pump format.
  2. Calculate total dynamic head instead of using well depth alone.
  3. Keep operating input within 30V to 48V DC and array open-circuit voltage below 60V.
  4. Plan any cable extension and submerged connection from the supplied 2m cable length.
  5. Confirm the final duty point and installation details with qualified local professionals.

Product FAQ

Review verified technical data, operating limits and the project information needed to evaluate this model.

What are the verified catalogue ratings for the 2DPC1.5-35-24-200?

The catalogue lists 24V rated voltage, 30V to 48V optimum DC input, 200W rated power, 1.5 m3/h maximum flow, 35m maximum head, a 3/4-inch outlet, 2m cable and solar-array open-circuit voltage below 60V.

Does the pump deliver 1.5 m3/h at a 35m head?

No. Maximum flow and maximum head are opposite hydraulic boundaries and should not be treated as one operating point. The required flow must be checked at the site's calculated total dynamic head.

What solar-array voltage is suitable for this model?

The catalogue states an optimum DC input range of 30V to 48V and requires array open-circuit voltage to remain below 60V. Module configuration must satisfy both limits under local temperature conditions.

What does the 2DPC series description confirm about construction?

It identifies this product as a 2-inch DC solar submersible pump with a plastic impeller. Other internal materials should not be assumed without additional approved technical documentation.

What project data does Rakour need before confirming this pump?

Provide the water source, bore or casing diameter, static and pumping water levels, elevation, pipe length and diameter, required flow or daily volume, outlet pressure and local solar conditions.

Match this pump to your site

Share the water source, required flow, total head and pipe route. Rakour will help check the operating point.

Request a quote