Rakour
48V Solar Surface Pump
Model DCPM15-14-48-550
48V Solar Surface Pump with 550W power, 15 m3/h maximum flow, and 14 m maximum head.
- Rated voltage
- 48V DC
- Rated power
- 550W
- Maximum flow
- 15 m3/h Catalogue maximum; actual flow depends on total head.
- Maximum head
- 14m Catalogue maximum; not the flow point at 15 m3/h.
- Outlet
- 1 1/2 in
- Cable length
- 0.6m
Product overview
48V Solar Surface Pump with 550W power, 15 m3/h maximum flow, and 14 m maximum head.
Model DCPM15-14-48-550
48V Solar Surface Pump
- Rated voltage
- 48V DC
- Rated power
- 550W
- Maximum flow
- 15 m3/h
- Maximum head
- 14m
Hydraulic data
The catalogue lists 15 m3/h maximum flow and 14m maximum head. These are boundary values, not one simultaneous operating point. Confirm the required flow at the calculated total dynamic head before selecting the pump.
- Calculate total dynamic head from water level, elevation, pipe friction and required outlet pressure.
- Do not assume the pump delivers 15 m3/h at 14m head.
- Confirm the final operating point against verified performance data before ordering.
Electrical data
Configure the array for a 60V to 90V operating input while keeping total open-circuit voltage below 120V.
- Rated voltage 48V DC
- Optimum DC input voltage 60V to 90V
- PV open-circuit voltage Less than 120V
Product features
Surface-mounted centrifugal pump
48V Solar Surface Pump with 550W power, 15 m3/h maximum flow, and 14 m maximum head.
Centrifugal surface pump
The catalogue confirms centrifugal surface pump for this series. Other internal materials should not be assumed without approved technical documentation.
48V DC electrical platform
The pump is rated at 48V DC with an optimum DC input range of 60V to 90V.
Defined hydraulic limits
Catalogue limits of 15 m3/h maximum flow and 14m maximum head support initial model screening.
Hydraulic performance
Use the maximum values as selection boundaries
The catalogue lists 15 m3/h maximum flow and 14m maximum head. These are boundary values, not one simultaneous operating point. Confirm the required flow at the calculated total dynamic head before selecting the pump.
- Calculate total dynamic head from water level, elevation, pipe friction and required outlet pressure.
- Do not assume the pump delivers 15 m3/h at 14m head.
- Confirm the final operating point against verified performance data before ordering.
Technical specifications
Hydraulic data
- Maximum flow
- 15 m3/h
- Maximum head
- 14m
- Outlet
- 1 1/2 in
Maximum flowMaximum catalogue value; flow falls as total head rises.
Maximum headMaximum catalogue value; it is not produced together with maximum flow.
Electrical data
- Rated voltage
- 48V DC
- Optimum DC input voltage
- 60V to 90V
- Rated power
- 550W
- PV open-circuit voltage
- Less than 120VThe complete array Voc must remain below this catalogue limit.
Construction and connection
- Series
- DCPM
- Pump format
- Surface-mounted centrifugal pump
- Pump type
- Centrifugal surface pump
- Cable length
- 0.6m
Recommended applications
Surface water transfer
A potential use where the required flow and total dynamic head remain inside the verified operating range.
Solar tank filling
The 48V DC model can be evaluated for daytime tank filling after daily volume and effective solar hours are calculated.
Low-head irrigation supply
It may supply a matched irrigation zone or storage tank when the required pressure and flow are confirmed.
Remote water transfer
It can be considered for off-grid transfer duties that match its electrical and hydraulic limits.
System configuration
-
Solar array
Configure the array for a 60V to 90V operating input while keeping total open-circuit voltage below 120V.
-
Compatible controller
Select a controller suitable for a 48V DC pump and the electrical limits of the complete system.
-
48V Solar Surface Pump
48V Solar Surface Pump with 550W power, 15 m3/h maximum flow, and 14 m maximum head.
-
Delivery line
Size the 1 1/2-inch connection, pipe route and outlet so avoidable friction does not consume available head.
Installation notes
- Confirm a stable, accessible installation position close to the water source.
- Calculate total dynamic head, including suction conditions, elevation and delivery-pipe losses.
- Keep operating input within 60V to 90V DC and array open-circuit voltage below 120V.
- Plan the electrical connection from the supplied 0.6m cable and keep all connections protected from water.
- Confirm the final duty point and installation details with qualified local professionals.
Product FAQ
Review verified technical data, operating limits and the project information needed to evaluate this model.
What are the verified catalogue ratings for the DCPM15-14-48-550?
The catalogue lists 48V rated voltage, 60V to 90V optimum DC input, 550W rated power, 15 m3/h maximum flow, 14m maximum head, a 1 1/2-inch outlet, 0.6m cable and solar-array open-circuit voltage below 120V.
Does the pump deliver 15 m3/h at a 14m head?
No. Maximum flow and maximum head are opposite hydraulic boundaries and should not be treated as one operating point. The required flow must be checked at the site's calculated total dynamic head.
What solar-array voltage is suitable for this model?
The catalogue states an optimum DC input range of 60V to 90V and requires array open-circuit voltage to remain below 120V. Module configuration must satisfy both limits under local temperature conditions.
What construction does the catalogue confirm for the DCPM15-14-48-550?
48V Solar Surface Pump. The catalogue confirms centrifugal surface pump for this series. Other internal materials should not be assumed without approved technical documentation.
What project data does Rakour need before confirming this pump?
Provide the water source, available suction conditions, elevation, pipe length and diameter, required flow or daily volume, outlet pressure and local solar conditions.
Match this pump to your site